Valley provides Fire Pump Testing and Cross-Connection Control Device Inspection and Certification (CCCDI). Annual fire pump testing and complete system inspections are required by your local fire department (NFPA#25-1998). Also, Illinois EPA Regulations require that the Backflow Prevention Assembly located in your building be inspected and certified annually. Our licensed inspectors will inspect your Backflow Prevention Assembly, and provide the proper certificate to governmental agencies and insurance carriers. It pleases our clients that we provide both the Fire Pump test, system inspection and backflow certification. They appreciate the "one call does it all" scheduling efficiency and a higher level of service provider accountability. Valley Fire's Core Inspection Services include: - Perform main drain tests, and tag each riser with the static and residual pressure
- Trip test dry pipe valves, test quick opening devices and drain low points if applicable
- Inspect, test and record anti-freeze system readings if applicable
- Time and adjust water flow switches to maintain a designated delay setting
- Operate control valves and test monitoring devices
- Inspect fire department connections to ensure they meet with local fire department requirements
- Test supervisory, local and electric alarms for proper operation
- Churn test fire pumps for proper operation and condition, if applicable
- Inspect sprinkler heads for proper temperature ratings, damage, corrosion, or obstructions
- Inspect sprinkler heads for the Central recall program
- Inspect water supply and gravity tanks if applicable
- Instruct personnel in system operation and procedures to follow should damage to the system occur
- Furnish a detailed report on the appropriate forms with recommendations on system function and
condition - Provide 24/7/365 emergency service
Fire Protection Equipment Must be Inspected and Certified Annually 
Legislation - NFPA - National Fire Protection Association ( NFPA-25_Chapters_4 & 5 )
By means of periodic inspections, tests, and maintenance, the equipment shall show to be in good operating condition or any defects or impairments shall be revealed. These tasks shall be performed by personnel who have developed competence through training and experience. - IL EPA - Illinois Environmental Protection Agency ( IL-EPA_Title_35.F.2.H.E.1 )
Each device shall be tested at least annually or more frequently if recommended by the manufacturer. Records submitted to the community public water supply shall be available for inspection by Agency personnel in accordance with IL Rev. Stat. 1983, ch. 111 ½, par. 1004(e).
Valley Fire Protection Systems
- Valley's Emergency Service Department has 10 fully-stocked service trucks on-call 24/7/365.
- Valley's full Insurance Coverage through Zurich American will meet ALL your insurance requirements.
- Valley inspects ALL your systems in one day, so as to not disturb company operations more than once
per year. - Valley technicians are professionally trained and NICET certified, and always adhere to NFPA 25
requirements. - Valley is OSHA certified and has earned one of the finest safety performance records in the industry.
Getting Started 1. Request a quote from Valley Fire Protection; sign the Inspection Proposal 2. When your building is due for its annual inspection, Valley will call you to schedule a convenient date and time 3. After inspection, copies of Inspection Reports are distributed as follows: - a copy is left at building being inspected
- a copy is given to the Local Fire Department (NFPA Requirement)
- a copy is mailed to your office (your Insurance Carrier may require a copy)
- a copy remains at our office in Batavia
|